+234 8146561114 (MTN) or
+2347015391124 (AIRTEL)

DESIGN AND CONSTRUCTION OF A PHASE SEQUENCE CHECKER FOR THREE PHASE SUPPLY

 

ABSTRACT

The project is designed to provide uninterrupted AC mains supply i.e., 220 volt to a single phase load. This is achieved by automatic changeover of the load from the missing phase to the next available phase in a 3 phase system.
It is often noticed that power interruption in distribution system is about 70% for single phase faults while other two phases are in normal condition. Thus, in any commercial or domestic power supply system where 3 phase is available, it is advisable to have an automatic changeover system for uninterrupted power to critical loads in the event of missing phase.
In this system auto selection is achieved by using a set of relays interconnected in such a way that if one of the relay feeding to the load remains energized always. Under the phase failure condition the corresponding step down transformer secondary delivers zero voltage which is duly rectified to DC and then fed to the logic gates comprising of AND & OR to switch on the next relay that delivers the power to the load.
It also has a provision of connecting to an inverter source which delivers uninterrupted power to the load incase all the 3 phases go missing. The project is supplied with three transformers connected to the 3 phases supply.
Further the project can be enhanced by incorporating power semiconductor devices such as thyristors/IGBTs for instantaneous changeover to the next available phase. This overcomes the drawback of the changeover time generally witnessed by relay switching operations.
TABLE OF CONTENTS

Title page
Certification
Dedication
Acknowledgement
Abstract

Table of contents

CHAPTER ONE

    1. Introduction
    2. Background of the project
    3. objective of the project
    4. significance of the project
    5. scope of the project
    6. Application of the project
    7. limitation of the project
    8. project organisation

CHAPTER TWO

    1. Review of Related Literatures
    2. Contactors
    3. Auxiliary Timer
    4. Circuit Breaker
    5. Indicator Lights

CHAPTER THREE

    1. Basic Principles
    2. Principles of Operation
    3. Circuit diagram

CHAPTER FOUR

    1. Research Design and Construction
    2. Project Construction
    3. Mounting of Components
    4. Packaging
    5. Precaution
    6. Testing

CHAPTER FIVE

    1.      Associated Fault and Remedies
    2.      Conclusion
    3.       Reference


 

CLICK HERE FOR MORE RELATED TOPICS/MATERIAL

This material is a complete and well researched project material strictly for academic purposes, which has been approved by different Lecturers from different higher institutions. We make abstract and chapter one visible for everyone.

All Project Topics on this site have complete 5(five) Chapters . Each Project Material include: Abstract + Introduction + etc + Literature Review + methodology + etc + Conclusion + Recommendation + References/Bibliography.

To "DOWNLOAD" the complete material on this particular topic above click "HERE"

Do you want our Bank Accounts? please click HERE

To view other related topics click HERE

To "SUMMIT" new topic(s), develop a new topic OR you did not see your topic on our site but want to confirm the availiability of your topic click HERE

Do you want us to research for your new topic? if yes, click "HERE"

Do you have any question concerning our post/services? click HERE for answers to your questions


For more information contact us through Any of the following means:

Mobile No :+2348146561114 or +2347015391124

Email address :engr4project@gmail.com

Watsapp No :+2348146561114



IF YOU ARE SATISFIED WITH OUR SERVICES, PLEASE DO NOT FORGET TO INVITE YOUR FRIENDS AND COURSEMATES TO OUR PAGE.