+234 8146561114 (MTN) or
+2347015391124 (AIRTEL)

DESIGN AND CONSTRUCTION OF AN INTELLIGENT EMERGENCY LIGHT SYSTEM

 



BY
 
EGBUDIWE INNOCENT .N
EE/2007/181
 
BEING A PROJECT SUBMITTED IN PARTIAL FULFILMENT OF THE REQUIREMENT FOR THE AWARD OF BACHELOR OF ENGINEERING (B.ENG) DEGREE IN ELECTRICAL/ELECTRONIC ENGINEERING CARITAS UNIVERSITY, AMORJI-NIKE ENUGU.

   
AUGUST 2017
      

 

CERTIFICATION

This is to certify that this work was carried out by, EGBUDIWE .N. INNOCENT of the department of Electrical/Electronic Engineering, Caritas University Amorji-nike, Enugu.
 
___________________                                   Date: _____________

Engr. E.C. Aneke 

Project Supervisor

___________________                                  Date: ________________ 
Engr. C.O Ejimofor 
Head of Department
 
__________________                                   Date: ________________
External supervisor                                              
 

DEDICATION

The work is dedicated to the almighty God who with all his conglomerate efforts made my dream come true.


ACKNOWLEDGEMENT

My Profound gratitude goes to God Almighty who gave me good health and the strength throughout the period of this project. To my parents and siblings, I say a very big thank you for your financial and moral support during and after the completion of this project. 

My special thanks also go to my supervisor Engr. E.C Aneke and together with all other lecturers of the department.

 

ABSTRACT

This project work is on design and construction of an intelligent emergency light system. An intelligent emergency light is an electronics device used in turning light ON during dark condition. Intelligent Emergency Light will turn on the Emergency light only during the Dark condition. Ordinary emergency light will be switched ON during the power failure condition. So that if there was a power failure in day time the ordinary emergency light will also be switched on. So there is a loss of power. Our system will continuously monitor the light falling on the LDR and when there was no sufficient light over the LDR & there is a power failure then it will switch on the Light. So that the place at which the circuit was connected will always in Bright. And if there is a power failure then the power to drive the emergency light was taken from the Battery supplied with the circuit. The Whole system was controlled by the 555 timer IC. It continuously monitors the Light in the Room and it will switch ON the emergency light if there is a power failure and the Room was Dark. 

 

 

CLICK HERE FOR MORE RELATED TOPICS/MATERIAL

This material is a complete and well researched project material strictly for academic purposes, which has been approved by different Lecturers from different higher institutions. We make abstract and chapter one visible for everyone.

All Project Topics on this site have complete 5(five) Chapters . Each Project Material include: Abstract + Introduction + etc + Literature Review + methodology + etc + Conclusion + Recommendation + References/Bibliography.

To "DOWNLOAD" the complete material on this particular topic above click "HERE"

Do you want our Bank Accounts? please click HERE

To view other related topics click HERE

To "SUMMIT" new topic(s), develop a new topic OR you did not see your topic on our site but want to confirm the availiability of your topic click HERE

Do you want us to research for your new topic? if yes, click "HERE"

Do you have any question concerning our post/services? click HERE for answers to your questions

You can also visit our facebook Page at fb.me/hyclas to view more our related construction (or design) pics


For more information contact us through Any of the following means:

Mobile No :+2348146561114 or +2347015391124 [Mr. Innocent]

Email address :engr4project@gmail.com

Watsapp No :+2348146561114

To View Our Design Pix: You can also visit our facebook Page at fb.me/hyclas for our design photos/pics.



IF YOU ARE SATISFIED WITH OUR SERVICES, PLEASE DO NOT FORGET TO INVITE YOUR FRIENDS AND COURSEMATES TO OUR PAGE.