DESIGN AND CONSTRUCTION OF FORWARD AND REVERSE CONTROL OF AN AC MOTOR USING TIMER RELAY
USER'S INSTRUCTIONS: The project work you are about to view is on "design and construction of forward and reverse control of an ac motor using timer relay". Please, sit back and study the below research material carefully. This project topic "design and construction of forward and reverse control of an ac motor using timer relay" have complete 5(five) Chapters. The complete Project Material/writeup include: Abstract + Introduction + etc + Literature Review + methodology + etc + Conclusion + Recommendation + References/Bibliography.Our aim of providing this "design and construction of forward and reverse control of an ac motor using timer relay" project research material is to reduce the stress of moving from one school library to another all in the name of searching for "design and construction of forward and reverse control of an ac motor using timer relay" research materials. We are not encouraging any form of plagiarism. This service is legal because, all institutions permit their students to read previous projects, books, articles or papers while developing their own works.
TITLE PAGE
BY
---
--/H2013/01430
DEPARTMENT OF ----
SCHOOL OF ---
INSTITUTE OF ---
APPROVAL PAGE
This is to certify that the research work, "design and construction of forward and reverse control of an ac motor using timer relay" by ---, Reg. No. --/H2007/01430 submitted in partial fulfillment of the requirement award of a Higher National Diploma on --- has been approved.
By
--- . ---
Supervisor Head of Department.
Signature………………. Signature……………….
……………………………….
---
External Invigilator
DEDICATION
This project is dedicated to Almighty God for his protection, kindness, strength over my life throughout the period and also to my --- for his financial support and moral care towards me.Also to my mentor --- for her academic advice she often gives to me. May Almighty God shield them from the peril of this world and bless their entire endeavour Amen.
ACKNOWLEDGEMENT
The successful completion of this project work could not have been a reality without the encouragement of my --- and other people. My immensely appreciation goes to my humble and able supervisor mr. --- for his kindness in supervising this project.
My warmest gratitude goes to my parents for their moral, spiritual and financial support throughout my study in this institution.
My appreciation goes to some of my lecturers among whom are Mr. ---, and Dr. ---. I also recognize the support of some of the staff of --- among whom are: The General Manager, Deputy General manager, the internal Auditor Mr. --- and the ---. Finally, my appreciation goes to my elder sister ---, my lovely friends mercy ---, ---, --- and many others who were quite helpful.
PROJECT DESCRIPTION: This work "design and construction of forward and reverse control of an ac motor using timer relay" research material is a complete and well researched project material strictly for academic purposes, which has been approved by different Lecturers from different higher institutions. We made Preliminary pages, Abstract and Chapter one of "design and construction of forward and reverse control of an ac motor using timer relay" visible for everyone, then the complete material on "design and construction of forward and reverse control of an ac motor using timer relay" is to be ordered for. Happy viewing!!!
Manually, the direction of rotation of any three-phase motor can be reversed by changing any of the motor leads. Since the motor is connected to the power line regardless of which direction it operates. In this work, instead of changing the direction of the motor manually a timer relay was used which is a type of relay constructed with a kind of “shock absorber” mechanism attached to the armature which prevents immediate, full motion when the coil is either energized or de-energized. This addition gives the relay the property of time-delay actuation.
This work deals with forward reverse of an ac motor delta used in every electrical industry involving industrial process automation control technology.
TABLE OF CONTENTS
COVER PAGE
TITLE PAGE
APPROVAL PAGE
DEDICATION
ACKNOWLEDGEMENT
ABSTRACT
CHAPTER ONE
INTRODUCTION
1.1 BACKGROUND OF THE PROJECT
- PURPOSE OF THE PROJECT
- OBJECTIVE OF THE PROJECT
- SIGNIFICANCE OF THE PROJECT
- APPLICATION OF THE PROJECT
- LIMITATION OF THE PROJECT
- PROBLEM OF THE PROJECT
CHAPTER TWO
LITERATURE REVIEW
- REVIEW OF THE STUDY
- DESCRIPTION OF AN AC INDUCTION MOTOR
- REVIEW OF OPERATING PRINCIPLES OF AN AC INDUCTION MOTOR
- HISTORICAL BACKGROUND OF AN AC INDUCTION MOTOR
- REVIEW OF RELATED STUDIES
- REVIEW OF DIFFERENT TYPES AC MOTOR CONTROL
CHAPTER THREE
SYSTEM METHODOLOGY
- DESIGN METHODOLOGY
- MATERIAL USED
- YSTEM DIAGRAM
- SYSTEM OPERATION
- DESCRIPTION OF ELECTRICAL PARTS USED
CHAPTER FOUR
- THERMAL OVER LOAD RELAY
- MOTOR STARTER WITH OVERLOAD PROTECTION
CHAPTER FIVE
- CONCLUSION
- RECOMMENDATION
- REFERENCES
CHAPTER ONE
1.0 INTRODUCTION
1.1 BACKGROUND OF THE STUDY
Three phase star-delta motors are constructed similarly to a direct online single phase motor, but the terminals for each winding are not terminated within the motor, instead they are brought out of the motor for control wiring to connect to.
Three phase star-delta motors are used for maximum talk, where the motor will try to start under a heavy load. A star-delta motor starts in two stages, controlled by equipment connected to it.
Forwarding and reversing of an ac motor is done using a push button switches. Depending on the choice of the operator, starting the circuit is selected via the forward or the reverse push button switches. When the forward push button switch is selected, the command is transferred to the relevant forward function of the circuit which activates the forward main coil (blue). The relevant auxiliary contacts of the forward main coil (blue) would then be actuated opposite its normal state, that is, a normally open contact would eventually switch to a close contact whereas a normally close contact would switch to an open contact.
The forward main contact (blue) closes to activate the star coil (brown) together with the timer coil (green), hence placing the motor terminal in the power circuit connected to a star configuration. After an elapsed time is reached, the timer contact (green) will release the star coil (brown) and transfers the command to the forward delta mode as a result of a completed circuit with the closing of the timer contact (green) along with the awaiting initially closed forward main contact (blue), thereby permitting power flow to the forward delta coil (dark blue). This final stage places the motor terminal in the power circuit configured to a delta connection.
Another forward main contact (blue) is connected in parallel across the forward push button switch to serve as a latching switch that keeps the forward main coil maintained energized after the operator releases the forward push button switch.
Conversely, when the reverse push button switch is pressed by the operator, all the related contacts of the reverse main coil (red) is activated which holds the reverse main coil maintained activated after releasing the reverse push button switch, then energizes the star coil (brown) and the timer coil (green), then switches to the reverse delta mode (orange) after the specified time set on the timer expires.
To manually interrupt the circuit, the operator only needs to press the stop push button switch to deactivate any energized coil in the control circuit to instantaneously isolate the power source to the motor. Another interrupting contact is the thermal overload contact (purple) which serves as an automatic shutoff switch that instantaneously opens the control circuit to shut down the motor when overload current greater than the rated capacity is detected from the electric motor.
Interlock contacts are also strategically placed on the control circuit as a protective measure. An auxiliary contact from the star contactor (brown) is connected in series before the two delta contactor coils to isolate both the forward delta coil and the reverse delta coil when the star contactor coil is active. Likewise, auxiliary contacts from both the forward and the reverse delta coils are also placed in series before the star coil to isolate power to the star coil should any one of the two delta coils be active to ensure the absence of power flow to the star coil when the control circuit is actively in the delta mode.
Auxiliary contacts from both forward and reverse coils are also placed opposite each coil so that one cannot activate without the other one deactivated first, meaning, the normally-closed forward main contact (blue) connected before the reverse main coil (red) will not permit the activation of the reverse main coil (red) while the forward main coil (blue) is activated, conversely, the normally-closed reverse main contact (red) connected before the forward main coil (blue) will not also permit the activation of the forward main coil (blue) while the reverse main coil (red) is activated.
The same condition applies to both the forward and the reverse delta coils. The opposing interlock contacts placed before the forward and the reverse delta coils also provides protective action by preventing the simultaneous activation of the forward and the reverse delta coils at the same time, that is, the normally-closed reverse main contact (red) connected before the forward delta coil (dark blue) will not permit the activation of the forward delta coil (dark blue) while the reverse main coil (red) is active, and the normally-closed forward main contact (blue) placed before the reverse delta coil (red) will not also permit the activation of the reverse delta coil (red) while the forward main coil (blue) is active.
To facilitate for a further understanding about the concept of the forward reverse star delta electric motor control circuit, a flowchart diagram is provided to serve as a schematic representation of the sequence of operation of the reversible star delta electric motor control circuit.
1.2 PURPOSE OF THE PROJECT
A large number of motors are being used for general purposes in our surroundings from house-hold equipments to machine tools in industrial applications. The electric motor is now a necessary and indispensable source of power in many industries. The function and the applications of these motors are wide-ranging. For the many applications, the forward and reverse control of the motor plays a major role, which can be done using a wide range of control strategies. |
The main purpose of this work is to control the forward and backward of an ac motor using timer relay. |
1.3 OBJECTIVE OF THE PROJECT |
1.4 SIGNIFICANCE OF THE PROJECT
Can be used to drive small conveyor belts in 2 directions and with dimmer would be able to handle both directional control and speed control.
It is also possible to use this circuit for any robotic application where directional control is needed with speed control such as RC helicopters’ or aircrafts’ propellers. "Single Phase Induction Motor Speed Control Using PWM AC Chopper Fan Applicaitons”.
1.5 SCOPE OF THE PROJECT
This work deals with forward reverse of an ac motor delta used in every electrical industry involving industrial process automation control technology.
Depending on the choice of the operator, starting the circuit is selected via the forward or the reverse push button switches. When the forward push button switch is selected, the command is transferred to the relevant forward function of the circuit which activates the forward main coil (blue). The relevant auxiliary contacts of the forward main coil (blue) would then be actuated opposite its normal state, that is, a normally open contact would eventually switch to a close contact whereas a normally close contact would switch to an open contact. The forward main contact (blue) closes to activate the star coil (brown) together with the timer coil (green), hence placing the motor terminal in the power circuit
1.6 APPLICATION OF THE PROJECT
This work is used in the following devices:
- Automatic gates
- Electronic bikes
- Swing machines
- Robotic controls
- Mobile air condition fans
- Ac operated drill machines
- Winding machines
- Electronic door controllers
- Electronic chairs (beauty parlor. Etc.)
1.7 LIMITATION OF THE PROJECT
This device only control the forward and reverse of the motor and is not able to control the motor speed.
1.8 PROBLEM OF THE PROJECT
The timer relay which acts as a switch is quite expensive compare to other types switches which are used as an external electrical equipment. This switch is the most troublesome parts of the device. This switch suffers from mechanical wear, which affects the motor performance.
CHAPTER TWO: The chapter one of this work has been displayed above. The complete chapter two of "design and construction of forward and reverse control of an ac motor using timer relay" is also available. Order full work to download. Chapter two of "design and construction of forward and reverse control of an ac motor using timer relay" consists of the literature review. In this chapter all the related work on "design and construction of forward and reverse control of an ac motor using timer relay" was reviewed.
CHAPTER THREE: The complete chapter three of "design and construction of forward and reverse control of an ac motor using timer relay" is available. Order full work to download. Chapter three of "design and construction of forward and reverse control of an ac motor using timer relay" consists of the methodology. In this chapter all the method used in carrying out this work was discussed.
CHAPTER FOUR: The complete chapter four of "design and construction of forward and reverse control of an ac motor using timer relay" is available. Order full work to download. Chapter four of "design and construction of forward and reverse control of an ac motor using timer relay" consists of all the test conducted during the work and the result gotten after the whole work
CHAPTER FIVE: The complete chapter five of "design and construction of forward and reverse control of an ac motor using timer relay" is available. Order full work to download. Chapter five of "design and construction of forward and reverse control of an ac motor using timer relay" consist of conclusion, recommendation and references.
To "DOWNLOAD" the complete material on this particular topic above click "HERE"
Do you want our Bank Accounts? please click HERE
To view other related topics click HERE
To "SUMMIT" new topic(s), develop a new topic OR you did not see your topic on our site but want to confirm the availiability of your topic click HERE
Do you want us to research your new topic? if yes, click "HERE"
Do you have any question concerning our post/services? click HERE for answers to your questions
For more information contact us through any of the following means:
Mobile No :+2348146561114 or +2347015391124 [Mr. Innocent]
Email address :engr4project@gmail.com
COUNTRIES THAT FOUND OUR SERVICES USEFUL
Australia, Botswana, Canada, Europe, Ghana, Ireland, India, Kenya, Liberia, Malaysia, Namibia, New Zealand, Nigeria, Pakistan, Philippines, Singapore, Sierra Leone, South Africa, Uganda, United States, United Kindom, Zambia, Zimbabwe, etc
Support: +234 8146561114 or +2347015391124
Watsapp No :+2348146561114
Email Address :engr4project@gmail.com
FOLLOW / VISIT US VIA: